Difference between revisions of "Stations"
From meteobridge
(45 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | |||
<!--T:1--> | <!--T:1--> | ||
<br />Meteobridge can handle a broad range of weather stations from consumer entry level up to prosumer/professional stations from Davis Instruments, PeetBros or Rainwise.<br /> | <br />Meteobridge can handle a broad range of weather stations from consumer entry level up to prosumer/professional stations from Davis Instruments, PeetBros or Rainwise.<br /> | ||
Line 16: | Line 15: | ||
|'''Davis'''<BR>Vantage Vue | |'''Davis'''<BR>Vantage Vue | ||
|Vantage Vue including wind, rain, pressure, indoor temperature, outdoor temperature sensors, but without UV or solar sensors. In order to connect Vue with Meteobridge it needs one of the Davis data loggers (serial or USB). If a serial logger is used, it needs to be set to 19.200 baud and a RS232-USB converter based on Prolific pl2303 or FTDI chipset is necessary. Storage capacity of Davis logger is not used at all. Meteobridge allows parallel use of the Vantage by a PC program, which connects to the Meteobridge on port 22222 (like with a Davis IP logger). Meteobridge can also pass through the connection to the Davis station to an additional PC weather program of your liking. Therefore, you can use Meteobridge <u>and</u> a PC weather program in parallel. | |Vantage Vue including wind, rain, pressure, indoor temperature, outdoor temperature sensors, but without UV or solar sensors. In order to connect Vue with Meteobridge it needs one of the Davis data loggers (serial or USB). If a serial logger is used, it needs to be set to 19.200 baud and a RS232-USB converter based on Prolific pl2303 or FTDI chipset is necessary. Storage capacity of Davis logger is not used at all. Meteobridge allows parallel use of the Vantage by a PC program, which connects to the Meteobridge on port 22222 (like with a Davis IP logger). Meteobridge can also pass through the connection to the Davis station to an additional PC weather program of your liking. Therefore, you can use Meteobridge <u>and</u> a PC weather program in parallel. | ||
+ | |- | ||
+ | |<center>[[File:wll.png]]</center> | ||
+ | |'''Davis'''<BR>WeatherLink Live | ||
+ | |WeatherLink Live can gather data from up to 8 Davis sensor arrays and does send data to the proprietary, subscription-based weather network "Davis WeatherLink". Apart from that the WeatherLink Live does also provide weather data in the LAN when requested. Meteobridge is able to read data from the unit and to make use of data from all connected sensor arrays. In order to connect to the WeatherLink Live Meteobridge needs to know the IP of the unit. | ||
+ | |- | ||
+ | |<center>[[File:airlinkx.png]]</center> | ||
+ | |'''Davis'''<BR>AirLink | ||
+ | |AirLink is a new sensor from Davis instruments that measures temperature, humidity and air quality by dense of particles in sizes 1, 2.5 and 10 microns. This sensor does not communicate with other Davis products via RF but directly connects to Davis cloud services and provides data in your local network by an API. All Meteobridge needs to know is the IP of the AirLink to read data from it. | ||
|- | |- | ||
|<center>[[File:meteostick.png]]</center> | |<center>[[File:meteostick.png]]</center> | ||
Line 60: | Line 67: | ||
|'''Fine Offset '''<BR>WH4000, WH2310 | |'''Fine Offset '''<BR>WH4000, WH2310 | ||
|These weather stations also rebranded as Tycon TP2700 are manufactured by Fine Offset Electronics and use a bit different protocol compared to the WH1080 and alike clones. Meteobridge makes use of live data, internal data logger functionality is not used. Stations can be connected via USB. UV/Solar sensor is used if present. | |These weather stations also rebranded as Tycon TP2700 are manufactured by Fine Offset Electronics and use a bit different protocol compared to the WH1080 and alike clones. Meteobridge makes use of live data, internal data logger functionality is not used. Stations can be connected via USB. UV/Solar sensor is used if present. | ||
+ | |- | ||
+ | |<center>[[File:gw1000x72.png|54px]]</center> | ||
+ | |'''Fine Offset/Ecowitt'''<BR>GW1000 | ||
+ | |This weather data gateway collects data from a couple of Ecowit / Fine Offset sensors and sensor arrays and is able to provide this data in the LAN. Meteobridge can read data from the GW1000 and supports all connected sensors. In order to connect to the GW1000 Meteobridge needs to know the IP of the GW1000. The GW1000 is also branded Froggit DP1500 or WH2650 in a housing that much looks like the first generation Observer IP WH2600. | ||
+ | |- | ||
+ | |<center>[[File:wittboy.png|36px]]</center> | ||
+ | |'''Fine Offset/Ecowitt'''<BR>GW2001 WittBoy | ||
+ | |This weather data gateway collects data from a couple of Ecowit / Fine Offset sensors and sensor arrays and is able to provide this data in the LAN. Meteobridge can read data from the GW2001 and supports all connected sensors. In order to connect to the GW2001 Meteobridge needs to know the IP of the GW2001. | ||
+ | |- | ||
+ | |<center>[[File:ecowittx72.png]]</center> | ||
+ | |'''Fine Offset/Ecowitt'''<BR>HP2551-C, HP3500, WH2910C, WH2320 | ||
+ | |These weather data consoles collect data from a couple of Ecowitt / Fine Offset sensors and sensor arrays and is able to upload data via "Custom Server" option to Meteobridge. Meteobridge supports all connected sensors. In order to upload data to the Meteobridge the Meteobridge URL "http://ip-of-meteobridge/public/ecowitt0.cgi" has to be specified in the console as "Custom Server" URL. "ecowitt0.cgi" is the right target if it is defined as the primary station in Meteobridge. If it is defined as the first additional station "ecowitt1.cgi" needs to be specified, etc. This allows Meteobridge to collect data from multiple Ecowitt consoles. | ||
+ | |- | ||
+ | |<center>[[File:ws980x70.png]]</center> | ||
+ | |'''Fine Offset'''<BR>WH2350 | ||
+ | |This weather station collects data from a couple of Fine Offset sensors and sensor arrays and is able to provide this data in the WLAN. Meteobridge can read data from the WH2350 and supports all connected sensors. In order to connect to the WH2350 Meteobridge needs to know the IP of the WH2350. The WH2350 is also branded Froggit WH4000SE, ELV WS980 or Ecowitt WS2320E. | ||
|- | |- | ||
|<center>[[File:oserverip.png]]</center> | |<center>[[File:oserverip.png]]</center> | ||
|'''Ambient Weather '''<BR>Observer IP | |'''Ambient Weather '''<BR>Observer IP | ||
− | |This LAN device uploads data from the Weather Observer line of weather sensors to Weather Underground. Meteobridge can also make use of the Oberserver IP. | + | |This LAN device uploads data from the Weather Observer line of weather sensors to Weather Underground. Meteobridge can also make use of the Oberserver IP. It is also known as WH2600. |
|- | |- | ||
|<center>[[File:ultimeter.png]]</center> | |<center>[[File:ultimeter.png]]</center> | ||
Line 71: | Line 94: | ||
|<center>[[File:mk3.png]]</center> | |<center>[[File:mk3.png]]</center> | ||
|'''Rainwise'''<BR>MkIII | |'''Rainwise'''<BR>MkIII | ||
− | |MkIII weather station from Rainwise is supported including wind, rain, pressure, outdoor temperature and humidity. Meteobridge can handle the old (white box) serial MKIIICC computer interface (with a RS232-USB converter based on pl2303 or FTDI) and the new (black box) CC-3000 computer interface. | + | |MkIII weather station from Rainwise is supported including wind, rain, pressure, outdoor temperature and humidity. Meteobridge can handle the old (white box) serial MKIIICC computer interface (with a RS232-USB converter based on pl2303 or FTDI) and the new (black box) CC-3000 computer interface and the IP-100 interface that connects to your LAN and uploads data to the Rainwise cloud services. |
|- | |- | ||
|<center>[[File:ws600.png]]</center> | |<center>[[File:ws600.png]]</center> | ||
− | |'''Lufft'''<BR>WS600/601/700 | + | |'''Lufft'''<BR>WS600/601/700/500/200 |
− | |WS600 and alike weather stations from Lufft are supported, when attached as USB serial device by a specific UMB component. Station needs to be configured on channel 1. Data provided is wind speed, wind direction, temperature, humidity, rain rate, rain total, solar radiation, uv index. Precipitation type is not evaluated by Meteobridge. | + | |WS600 and alike weather stations from Lufft are supported, when attached as USB serial device by a specific UMB component. Station needs to be configured on channel 1. Data provided is wind speed, wind direction, temperature, humidity, pressure, rain rate, rain total, solar radiation, uv index. Precipitation type is not evaluated by Meteobridge. |
+ | |- | ||
+ | |<center>[[File:ventus.png]]</center> | ||
+ | |'''Lufft'''<BR>Ventus V200A | ||
+ | |V200A is a station from Lufft that focuses on wind and temperature. It is supported by Meteobridge when attached as USB serial device by a specific UMB component. Station needs to be configured on channel 1. Data provided is wind speed, wind direction, temperature and pressure. | ||
+ | |- | ||
+ | |<center>[[File:thies.png]]</center> | ||
+ | |'''Thies'''<BR>Clima Sensor US | ||
+ | |Clima Sensor US is supported. It needs to be connected via a RS-485/422 to USB converter to the Meteobridge. | ||
+ | |- | ||
+ | |<center>[[File:gmx600-small.png]]</center> | ||
+ | |'''Gill'''<BR>GMX600 | ||
+ | |Gill Instrumets GMX600 station is supported via Gill's RS232-to-USB interface. | ||
|- | |- | ||
|<center>[[File:acurite.png]]</center> | |<center>[[File:acurite.png]]</center> | ||
|'''Acurite'''<BR>1025/1035/1525 | |'''Acurite'''<BR>1025/1035/1525 | ||
|USB enabled weather stations from Acurite are supported including wind, rain, pressure, outdoor and indoor temperature and humidity. Meteobridge directly connects to the USB interface of the Acurite console. Important: Acurite console has to be switched to USB mode 3. Warning: Inside humidity is not reported correctly. | |USB enabled weather stations from Acurite are supported including wind, rain, pressure, outdoor and indoor temperature and humidity. Meteobridge directly connects to the USB interface of the Acurite console. Important: Acurite console has to be switched to USB mode 3. Warning: Inside humidity is not reported correctly. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
|<center>[[File:ws2300.png]]</center> | |<center>[[File:ws2300.png]]</center> | ||
Line 92: | Line 123: | ||
|'''LaCrosse / ELV'''<BR>WS300PC/444/500 and various clones (WS550/777/888, WDC7000) | |'''LaCrosse / ELV'''<BR>WS300PC/444/500 and various clones (WS550/777/888, WDC7000) | ||
|WS300 weather station and clones are supported and connected via USB. | |WS300 weather station and clones are supported and connected via USB. | ||
+ | |- | ||
+ | |<center>[[File:wflow.png]]</center> | ||
+ | |'''WeatherFlow'''<BR>AIR, SKY and TEMPEST | ||
+ | |AIR, SKY and the new all-in-one TEMPEST stations are supported. Meteobridge connects to the HUB delivered with the AIR/SKY/TEMPEST units and reads out data via the local LAN/WLAN. | ||
+ | |- | ||
+ | |<center>[[File:w835.png]]</center> | ||
+ | |'''Ventus'''<BR>W835 | ||
+ | |W835 weather station is supported and connected via USB. | ||
+ | |- | ||
+ | |<center>[[File:rs500.png]]</center> | ||
+ | |'''ELV'''<BR>RS500 Climate Logger | ||
+ | |RS500 room climate logger is supported and connected via USB. | ||
+ | |- | ||
+ | |<center>[[File:labjackhv.gif]]</center> | ||
+ | |'''LabJack U3'''<BR>Voltage Measurement | ||
+ | |Both LabJack U3 variants ("HV" for voltages between +20V/-10V and "LV" for voltages between 3.6V/0V) are supported. USB conncted LabJack U3 has multiple inputs for voltage measurements and two inputs for measuring frequencies, periods and duty cycles. This box can be a bridge to connect non-standard weather sensors to Meteobridge. | ||
|} | |} | ||
Revision as of 22:07, 7 February 2024
Meteobridge can handle a broad range of weather stations from consumer entry level up to prosumer/professional stations from Davis Instruments, PeetBros or Rainwise.
Weather station | Description | |
---|---|---|
Davis Vantage Pro2, Pro1 (except firmware A) |
Vantage Pro including wind, rain, pressure, UV, solar radiation, indoor temperature, outdoor temperature sensors. In order to connect Vantage with Meteobridge it needs one of the Davis data loggers (serial or USB). If a serial logger is used, it needs to be set to 19.200 baud and a RS232-USB converter based on Prolific pl2303 or FTDI chipset is necessary. Storage capacity of Davis logger is not used at all. Meteobridge allows parallel use of the Vantage by a PC program, which connects to the Meteobridge on port 22222 (like with a Davis IP logger). Meteobridge can also pass through the connection to the Davis station to an additional PC weather program of your liking. Therefore, you can use Meteobridge and a PC weather program in parallel. | |
Davis Vantage Vue |
Vantage Vue including wind, rain, pressure, indoor temperature, outdoor temperature sensors, but without UV or solar sensors. In order to connect Vue with Meteobridge it needs one of the Davis data loggers (serial or USB). If a serial logger is used, it needs to be set to 19.200 baud and a RS232-USB converter based on Prolific pl2303 or FTDI chipset is necessary. Storage capacity of Davis logger is not used at all. Meteobridge allows parallel use of the Vantage by a PC program, which connects to the Meteobridge on port 22222 (like with a Davis IP logger). Meteobridge can also pass through the connection to the Davis station to an additional PC weather program of your liking. Therefore, you can use Meteobridge and a PC weather program in parallel. | |
Davis WeatherLink Live |
WeatherLink Live can gather data from up to 8 Davis sensor arrays and does send data to the proprietary, subscription-based weather network "Davis WeatherLink". Apart from that the WeatherLink Live does also provide weather data in the LAN when requested. Meteobridge is able to read data from the unit and to make use of data from all connected sensor arrays. In order to connect to the WeatherLink Live Meteobridge needs to know the IP of the unit. | |
Davis AirLink |
AirLink is a new sensor from Davis instruments that measures temperature, humidity and air quality by dense of particles in sizes 1, 2.5 and 10 microns. This sensor does not communicate with other Davis products via RF but directly connects to Davis cloud services and provides data in your local network by an API. All Meteobridge needs to know is the IP of the AirLink to read data from it. | |
smartbedded Meteostick for RF reception of Davis and Fine Offset sensor arrays |
Meteostick reads RF signals from Davis Vue and Vantage Pro 2 sensors (US, EU and AU models) directly and makes data accessible without need of a Davis Console/Envoy and Logger. Indoor humidity is not provided, indoor temp is not reported accurately, because the sensor in the USB stick sized device heats up a bit during operation. When used with Meteobridge FW 1.4 or newer, no USB hub is needed. Use of a USB cradle is recommended to bring some distance between the RF noise emitting Meteobridge and the Meteostick. Since Meteostick firmware 2.2 data from Davis repeaters is also supported. Since Meteostick firmware 2.0 also data from outdoor sensor array (WH24) of Fine Offset HP-100x (aka Ambientweather Observer WS-100x) can be received (US and EU models). You find more details about Meteostick here. Remark: Meteobridge does not offer pass through options for Meteostick as with the Davis loggers. | |
Oregon WMR968 (US), WMR928 (EU) |
This model has a RS232 connector that needs a RS232-USB converter (based on FTDI or Prolific pl2303 chipset). Station does not provide UV or solar sensors. | |
Oregon WMR100, WMR88 |
This model has a USB connector that can be connected to the Meteobridge client (with a USB 2.0 hub inbetween). An optional UV sensor is supported as well. | |
Oregon WMR89, WMR89A |
This model has a USB connector that can be connected to the Meteobridge client (with a USB 2.0 hub inbetween). An optional UV sensor is supported as well. | |
Oregon WMR200 |
This model has a USB connector that can be connected to the Meteobridge client (with a USB 2.0 hub inbetween). Internal datalogger of WMR200 will not be used by Meteobridge. WMR200 has problems in reporting actual sensor readings, when data logger is completely filled. It is recommended to set the data logging interval to the maximum (longest duration). This takes care that the data logger will not reach its capacity for months. However, you should take care to empty the data logger's buffer from time to time manually at the WMR200 base station. Beside the standard sensors it can also support UV sensors. | |
Oregon WMR300 |
This model has a USB connector that can be connected to the Meteobridge client (with a USB 2.0 hub inbetween). Internal datalogger of WMR300 will not be used by Meteobridge. | |
Oregon WMRS200 |
This station is like a WMR100 with sensors from WMR200 but without any display. WMRS200 is connected to Meteobidge USB port (as WMR200) and is also powered by the USB connector. | |
Meade TE923, TE827, TE821, DV928, W831 |
These weather stations are connected via USB and are sold with various brand names (Mebus, Irox, Honeywell, Nexus, Ventus). Meteobridge supports recent hardware versions which provide live weather data on the USB port. Internal data logger functionality of TE923 is not used by Meteobridge. Station is connected via USB (with a USB 2.0 hub inbetween). | |
LaCrosse WS1640 |
This weather stations is connected via USB and is from an USB point of view identical to the ones above from Meade, Mebus, Irox, etc. Meteobridge supports recent hardware versions which provide live weather data on the USB port. Internal data logger functionality is not used by Meteobridge. Station is connected via USB (with a USB 2.0 hub inbetween). | |
Ambient Weather WS1090, WS2080 |
These weather stations manufactured by Fine Offset Electronics (WH1080, WH2080, WH3080) are also branded as Watson W-8681, WX-2008, National Geographic 265 NE, Elecsa 6975/ 6976, etc. Meteobridge makes use of live data, internal data logger functionality is not used. Stations can be connected via USB. UV sensors is used if present. | |
Fine Offset WH4000, WH2310 |
These weather stations also rebranded as Tycon TP2700 are manufactured by Fine Offset Electronics and use a bit different protocol compared to the WH1080 and alike clones. Meteobridge makes use of live data, internal data logger functionality is not used. Stations can be connected via USB. UV/Solar sensor is used if present. | |
Fine Offset/Ecowitt GW1000 |
This weather data gateway collects data from a couple of Ecowit / Fine Offset sensors and sensor arrays and is able to provide this data in the LAN. Meteobridge can read data from the GW1000 and supports all connected sensors. In order to connect to the GW1000 Meteobridge needs to know the IP of the GW1000. The GW1000 is also branded Froggit DP1500 or WH2650 in a housing that much looks like the first generation Observer IP WH2600. | |
Fine Offset/Ecowitt GW2001 WittBoy |
This weather data gateway collects data from a couple of Ecowit / Fine Offset sensors and sensor arrays and is able to provide this data in the LAN. Meteobridge can read data from the GW2001 and supports all connected sensors. In order to connect to the GW2001 Meteobridge needs to know the IP of the GW2001. | |
Fine Offset/Ecowitt HP2551-C, HP3500, WH2910C, WH2320 |
These weather data consoles collect data from a couple of Ecowitt / Fine Offset sensors and sensor arrays and is able to upload data via "Custom Server" option to Meteobridge. Meteobridge supports all connected sensors. In order to upload data to the Meteobridge the Meteobridge URL "http://ip-of-meteobridge/public/ecowitt0.cgi" has to be specified in the console as "Custom Server" URL. "ecowitt0.cgi" is the right target if it is defined as the primary station in Meteobridge. If it is defined as the first additional station "ecowitt1.cgi" needs to be specified, etc. This allows Meteobridge to collect data from multiple Ecowitt consoles. | |
Fine Offset WH2350 |
This weather station collects data from a couple of Fine Offset sensors and sensor arrays and is able to provide this data in the WLAN. Meteobridge can read data from the WH2350 and supports all connected sensors. In order to connect to the WH2350 Meteobridge needs to know the IP of the WH2350. The WH2350 is also branded Froggit WH4000SE, ELV WS980 or Ecowitt WS2320E. | |
Ambient Weather Observer IP |
This LAN device uploads data from the Weather Observer line of weather sensors to Weather Underground. Meteobridge can also make use of the Oberserver IP. It is also known as WH2600. | |
Peet Bros Ultimeter 100, 800, 2100 |
Ultimeter weather stations from Peet Bros are supported. Wind, rain, pressure, indoor and outdoor temperature and humidity are used. Station needs to be set to "data logging", "packet" or "complete record (preferred) mode with 2400 baud transfer rate. Station needs a RS232-USB converter based on Prolific pl2303 or FTDI chipset. | |
Rainwise MkIII |
MkIII weather station from Rainwise is supported including wind, rain, pressure, outdoor temperature and humidity. Meteobridge can handle the old (white box) serial MKIIICC computer interface (with a RS232-USB converter based on pl2303 or FTDI) and the new (black box) CC-3000 computer interface and the IP-100 interface that connects to your LAN and uploads data to the Rainwise cloud services. | |
Lufft WS600/601/700/500/200 |
WS600 and alike weather stations from Lufft are supported, when attached as USB serial device by a specific UMB component. Station needs to be configured on channel 1. Data provided is wind speed, wind direction, temperature, humidity, pressure, rain rate, rain total, solar radiation, uv index. Precipitation type is not evaluated by Meteobridge. | |
Lufft Ventus V200A |
V200A is a station from Lufft that focuses on wind and temperature. It is supported by Meteobridge when attached as USB serial device by a specific UMB component. Station needs to be configured on channel 1. Data provided is wind speed, wind direction, temperature and pressure. | |
Thies Clima Sensor US |
Clima Sensor US is supported. It needs to be connected via a RS-485/422 to USB converter to the Meteobridge. | |
Gill GMX600 |
Gill Instrumets GMX600 station is supported via Gill's RS232-to-USB interface. | |
Acurite 1025/1035/1525 |
USB enabled weather stations from Acurite are supported including wind, rain, pressure, outdoor and indoor temperature and humidity. Meteobridge directly connects to the USB interface of the Acurite console. Important: Acurite console has to be switched to USB mode 3. Warning: Inside humidity is not reported correctly. | |
LaCrosse WS2300 |
WS2300 weather station is supported. Warning: WS2300 can deliver sporadic false weather data readings caused by interface problems. WS2300 needs a RS232-USB converter witch pl2303 or FTDI chipset. | |
LaCrosse / ELV WS300PC/444/500 and various clones (WS550/777/888, WDC7000) |
WS300 weather station and clones are supported and connected via USB. | |
WeatherFlow AIR, SKY and TEMPEST |
AIR, SKY and the new all-in-one TEMPEST stations are supported. Meteobridge connects to the HUB delivered with the AIR/SKY/TEMPEST units and reads out data via the local LAN/WLAN. | |
Ventus W835 |
W835 weather station is supported and connected via USB. | |
ELV RS500 Climate Logger |
RS500 room climate logger is supported and connected via USB. | |
LabJack U3 Voltage Measurement |
Both LabJack U3 variants ("HV" for voltages between +20V/-10V and "LV" for voltages between 3.6V/0V) are supported. USB conncted LabJack U3 has multiple inputs for voltage measurements and two inputs for measuring frequencies, periods and duty cycles. This box can be a bridge to connect non-standard weather sensors to Meteobridge. |
Remark: All stations connected via USB will need a small cheap USB 2.0 hub to be connected to Meteobridge, when TP-Link platform (MR3020, MR3040, WR703N) or D-Link (DIR-505) is used. Reason is a limitation in Atheros chipset in these platforms. Any passive USB 2.0 router for a few Euros/Dollars should do. When ASUS WL-330N3G is used as platform, no USB hub is needed.
Not supported stations are LaCrosse 3600, 2800, 2500, 2000, Acurite Access. </translate>